| Company | Reference | Project / Site | Pc | Year of Realization |
|---|---|---|---|---|
| Energetika Třinec, a.s. | Rekonstruction and reblading of 10 MW condensing steam turbine, type specification T 9,8 -1,8/0,12. | Třinec / Czech Republic | 1 | 2001 |
| MVA | Project, design, manufacture, delivery, putting into operation of 5,6 MW, backpressure steam turbine, type specification R 5,6 - 3,8/0,32 | Bielefeld / Germany | 1 | 2001 |
| Elektrárna Kolín, a.s. | Project, design, manufacture, delivery, putting into operation of 560 kW, backpressure steam turbine, type specification R 0,56 - 1,1/0,2. | Kolín / Czech Republic | 1 | 2001 |
| Sokolovská uhelná, a.s. | Inspection and repair of 55 MW condensing steam turbine, type specification PP 55 - 13,0/3,5/0,5. | Vřesová / Czech Republic | 1 | 2001 |
| Sokolovská uhelná, a.s. | Inspection and repair of 60 MW condensing steam turbine, type specification PP 57 - 6,6/3,5/0,55. | Vřesová / Czech Republic | 1 | 2001 |
| S.I.I.C.Cairo | Planning, design and manufacture, delivery, commisioning of 4,5 MW backpressure steam turbine, type specification R 4,5 - 2,2/0,3. | Kous / Egypt | 1 | 2000 |
| Cinergetika Ú/L | Turbine modification, modernization, power increase from 6 MW to 8,6 MW, turbine base plate modification, generátor replacement (biger output), type specification PR 8,6 - 6,0/1,5/0,7. | Ústí nad Labem / Czech Republic | 1 | 2000 |
| Teplárna Otrokovice, a.s. | Overhaul and connection to the 25MW backpressure parent kontrol systém, type specification PR 25 - 9,0/1,5/0,7. | Otrokovice / Czech Republic | 1 | 2000 |
| Sokolovská uhelná, a.s. | Turbine modernization, replacement of parts in turbine steam inlet section, reblading of some rows of 55MW turbine. Type specification PP 55 - 13,0/3,5/0,5. | Vřesová / Czech Republic | 1 | 2000 |
| LOBBE, Switzerland | Planning, design and manufacture of condensing steam turbine with 14500/1500 gearbox, type specification K 1,6 - 2,0. | Dąbrowa Górnicza / Poland | 1 | 2000 |
| Moravskoslezské teplárny, a.s. | 12 MW backpressure steam turbine modification and reblading, type specification R 12 - 3,6/0,25. | Karviná / Czech Republic | 1 | 2000 |
| Kaučuk, a.s. | Planning, design, manufacture and delivery of 25 MW h.-p. stage for 30 MW condensing steam turbine, reblading of m.-p. and I.-p. stages. Power increase from 30 MW to 33 MW, type specification PT 33-9,0/1,0/0,12. | Kralupy n/Vltavou / Czech Republic | 1 | 2000 |
| Vihorlat, a.s. | 6 MW condensing steam turbine inspection and repair, type specification P 6 - 3,5/0,6 (ŠKODA). | Snina / Slovakia | 1 | 2000 |
| Cukrovar NOVA, a.s. | 10 MW backpressure steam turbine inspection and repair, type specification R 10 - 5,9/0,7. | Sereď / Slovakia | 1 | 2000 |
| SSE š.p. Žilina, závod Tepláreň Martin | 32 MW backpressure steam turbine repair, turbine base plate modification. Type specification PR 32 - 9,0/0,8/0,17. | Martin / Slovakia | 1 | 2000 |
| Slovenské elektrárne, a.s. | 32 MW condensing steam turbine overhaul, oil system and control system modification - type specification T 32 - 6,95/0,25. | Nováky / Slovakia | 1 | 2000 |
| Povážské strojárne, a.s. - Energetika | Overhaul of 6 MW backpressure steam turbine, reblanding, type specificaton R 6 - 3,5/0,6. | Povážská Bystrica / Slovakia | 1 | 2000 |
| Vihorlat, a.s. | Overhaul and repair of 6 MW back-pressure turbine, type specification R 6 - 3,5/0,5. | Snina / Slovakia | 1 | 1999 |
| Tp Bratislava | PR 6,4 - 1,6/0,7 steam turbine repair. | Bratislava / Slovakia | 1 | 1999 |
| LOVOCHEMIE,a .s. | General overhaul of PP 9 - 3,7/1,1/0,4 steam turbine. | Lovosice / Czech Republic | 1 | 1999 |
EKOL, spol. s r.o. is a respected European manufacturer and supplier of heat and power generating plants...